| Results Provided |
|
| Test Speed | Complete results in 8 minutes |
| Data Storage | Over 8,000 sets of results onboard, expandable with USB connection to other storage systems |
| Quality Control (QC) | Levey-Jennings plots are automatically generated; Daily Check, Haematology and CD4 with 2 levels each; log for QC data recorded as mean, SD and CV |
| Dimensions (HxWxD) | 35.4 x 25.0 x 33.7 cm (13.9 x 9.8 x 13.3 inch) |
| Weight | Under 12 kg (26.5 lb) |
| Power Source | Compatible with most supplies including AC and DC; requires only 150 Watts. Can operate from Battery Pack with Solar Panel for charging and operating time extension |
| Reagent Stability | CD4NOW™ reagents are insensitive to light and do not require cold chain shipment. See CD4NOW Reagent Kit 100 for more information. |
| Maintenance | A single service contract covers the system maintenance; the LED is long lasting and shipped with permanent alignment |
| Sample Requirements | One standard K2 EDTA Vacutainer® tube of whole blood, filled to full capacity |
In a low-to-medium throughput clinic or mobile facility, typically in
resource-limited regions
The essential haematology parameters for effective medical
decision-making and those parameters needed in HIV patient care:
- CD4 Absolute Count and CD4%
- Total White Blood Cell (WBC) Count
- Haemoglobin
- Lymphocyte Count and Percent
- Monocyte Count and Percent
- Neutrophil Count and Percent
- Eosinophil Count and Percent
Only one patient sample can be tested at a time.
Less than 8 minutes
8,000 patient records on the instrument, expandable to 50,000
patient records with a supplied USB memory stick
Blood volume of no less than 0.5 mL (millilitres) in the tube;
uses only 40 µL (microlitres) for sample analysis. Blood tube
must be drawn to full capacity.
The phlebotomist must collect the sample into a closed-cap K2
EDTA Vacutainer style tube. Syringe draws are not allowed and
no other type of tube may be used. All required phlebotomy
equipment is included in the CD4NOW™ Reagent Kit 100.
Minimal technical training is required. Please contact PointCare
for details of our operator training programme.
There are minimal operator risks. The testing procedure
starts and ends with a single closed-cap sample – the operator
is not exposed to the bio-hazard of handling open blood tubes,
manipulating caps and pipettes, nor incubating and reloading
samples. No manual sample preparation or sample handling
is required.
All supplies required are included in the CD4NOW Reagent Kit
100 (P/N 36000). To order new supplies, please contact your local
distributor or PointCare.
PointCare customers report savings from a number of areas:
- No reagent spoilage. PointCare’s heat-stable reagents are stable to 42° Celsius, and can handle short periods of high temperatures.
- No loss to follow-up: customers report they eliminate the 20 – 40% loss to follow-up they experienced with other CD4 systems.
- Lower operating costs: no laser to replace, and substantially more up-time.
- No cost to provide cold chain.
You can store your reagents without refrigeration, and they are
not light sensitive.








To view or print the PointCare brochures (from the brochures tab)
requires Adobe® Reader®, which is available as a free download from the Adobe web site.